EF TYPE

For Network And Application

 

LTE 100U Series 100W Multiplee Output Switching Power Supply

 

 

   >>  VOLTAGE: 11 VDC TO 12 VDC, FULL RANGE  

   >> CURRENT: 1.25 ARMS. MAX.@11VDC 7.7W LOAD

                          0.98 ARMS. MAX.@14VDC 7.7W LOAD

   >> INRUSH SURGE CURRENT

 

   >>   OUTPUT WATTAGE:7.7 WATTS MAX. (CONVECTION RATING)

   >>   LINE REGULATION :+/- 1% TYPICAL

   >>   LOAD REGULATION:MAIN OUTPUTS +/- 5%, AUX. OUTPUTS +/- 5% TYPICAL

   >>   NOISE & RIPPLE 1% TYPICAL AT FULL LOAD

   >>   OVERSHOOT/UNDERSHOOT±10% MAX.@TURN-ON/ TURN-OFF

 


VOLTAGE (Vdc)
LOAD RANGE (A)
LINE REGULATION
LOAD REGULATION (NOTE 1)
RIPPLE & NOISE (NOTE 2)
MIN
RATED
MAX/ PEAK
V1
-70V
0.01A
0.06A
--
±0.5%
 
-66.5~-73.5Vdc (±5.0%)
700mVp-p (1%)
V2
-25V
0.014A
0.14A
--
-23.75~-26.25Vdc (±5.0%)
250mVp-p (1%)

Note:

1. Load regulation is tested at min. to 100% of rated load and other outputs are set at 50% of rated load.

2. Peak-to-peak for rated load@12Vdc; Measurements with a 20MHZ bandwidth and terminated with a 10uF electrolytic CAP. in parallel with a 0.1uF ceramic Cap.

 

   >>   OPERATING TEMPERATURE:0°C TO 50°C AMBIENT, DERATED EACH OUTPUT AT -2.5% PER °C FROM 50°C TO 70°C

   >>   STORAGE TEMPERATURE: -40°C TO 85°C

   >>   HUMIDITY: OPERATING, NON-CONDENSING, 5% TO 95%

   >>   VIBRATION: RANDOM OPERATING 2.4 GRMS/MAX. 3 AXES 50~500Hz 10 MINUTES/AXIS

   >>   SHOCK: OPERATING HALF SINE 20 GPK/MAX. 3 AXES 10mS 6 SHOCKS TOTAL

 

   >>   EFFICIENCY: @11VDC WITH FULL LOAD >75 %, AND @14VDC WITH FULL LOAD >75%

   >>   TURN-ON TIME: @12VDC WITH FULL LOAD < 1 SEC